EOS 140
High performance barries
for vending machines
Dimensions
23 x 140mm
Thickness starting from
4mm
Installation range
from 50mm to 8m
View in 3D
Download
3D models
Get 3D models in STP format of the EOS 140 series.
Technical documentation
Download the full technical documentation for the EOS 140 series
EOS 140 Models
Model | Resolution (mm) | N. of beams | Protected height (mm) | Body lenght (mm) | Rensponse time (ms) |
---|---|---|---|---|---|
EOS 4-140 | 4 | 16 | 146 | 140 | 1,9 |
EOS 8-140 | 8 | 8 | 146 | 140 | 1,0 |
Model | Resolution (mm) | N. of beams | Protected height (mm) | Body lenght (mm) | Rensponse time (ms) |
---|---|---|---|---|---|
EOS 4-140 | 4 | 16 | 146 | 140 | 1,9 |
EOS 8-140 | 8 | 8 | 146 | 140 | 1,0 |
Technical specification
Characteristic | Value | |
---|---|---|
Resolution | 4 - 8mm | |
Sensible height | 130 mm | |
Response time | 0,96 - 1,92 ms | |
Installation range | da 50mm a 8m | |
Supply voltage | 24Vcc +/-20% | |
Operating temperature | from -20 to +50°C (based on the options selected) | |
LED indications | TX: Green led, blinking with test activated. | |
RX: Green / red LED | ||
Outputs | push/pull, Dark ON or Dark OFF, 50mA max, protected from short circuits | |
Immunità alla luce | up to 200000 Lux | |
Body lenght | 140mm | |
Body width | from 23mm (based on the options selected) | |
Thickness | from 4mm (based on the options selected) | |
Distance between mounting holes | 130mm |
Available options
Optics
Front
Photodiodes positioned parallel to the mounting holes.
Side
Photodiodes positioned perpendicular to the mounting holes.
Sensibility adjustment
Adjustable sensibility via mounted trimmer located in four possible positions depending on the choosed model.
Output mode selection
Jumper
Output mode selection via mounted jumper located in four possible positions based on model.
DIP Switch
Output mode selection via DIP switch.
External Selector
Output mode selection via an external wire connected to 0V or 24V.
Connections
MODU
AMPMODU MOD II connector for power supply and output, mounted in two different positions.
MTA
MTA connector for power supply, output and interconnection, mounted in four different positions.
Cable
M12 cable with a standard length of 30cm for power supply and output.
M8 cable with a standard length of 30cm for power supply and output.
Customizable cable.
Timer
Standard
Standard timer of 20ms.
Adjustable
Adjustable timer via mounted trimmer.
1ms
Fixed timer of 1ms.
Features
Tropicalization
Allows the barriers to work correctly even in high humidity environments.
Low temperature
Option that allows barriers to work in temperatures down to -20°C, such as refrigerated vending machines.
Test input
Option that simulates beam interruption to check the correct operation of the system.
Can be activated externally.
Code
Option prevent interference between multiple nearby sensors encoding the communication between emitter and receiver.
The code can be set using an internal DIP switch.